pve-container (5.0.10) bookworm; urgency=medium * api: status: move config locking from API handler into the task worker to avoid potentially blocking the API daemon * fix #5160: fix move-mount regression for mount point hotplug * api: container index: fix return type of vmid to ensure its an integer * pct: fsck: also clean-up (unmap) any mounted volume when the fsck command failed * ensure that device passthrough changes do not get written to the config even though they fail basic validation like if the device exists * fix #4474: api: add overrule-shutdown parameter to stop endpoint * fix #4846: avoid setting the deprecated noacl mount option on ext4 * firewall: add handling for new nftables based firewall implementation, which currently is a opt-in drop-in replacement for the older iptables- based one. -- Proxmox Support Team Fri, 19 Apr 2024 20:33:01 +0200 pve-container (5.0.9) bookworm; urgency=medium * config: schema: remove duplicate attribute assignment for mpX * fix #5194: pct: delete environment variables set by pve * pct: drop completion helper for target storage on remote-migration * pct: add keep-env option to the 'enter' and 'exec' command -- Proxmox Support Team Fri, 15 Mar 2024 10:24:22 +0100 pve-container (5.0.8) bookworm; urgency=medium * sdn: pass vmid and hostname to allow requesting a new mapping -- Proxmox Support Team Wed, 22 Nov 2023 14:11:52 +0100 pve-container (5.0.7) bookworm; urgency=medium * allow passing raw device nodes through to containers * recommend libpve-network-perl for SDN support * initial support for dhcp ip allocation in dhcp-enabled SDN zones - Proxmox Support Team Tue, 21 Nov 2023 15:37:14 +0100 -- Proxmox Support Team Tue, 21 Nov 2023 15:45:04 +0100 pve-container (5.0.6) bookworm; urgency=medium * api: network: add endpoint to get interfaces details like configured IPs * setup: fix architecture detection for NixOS containers * setup base: disable sysfs debug mounts via systemd presets, used by Debian 12+, Fedora 37+, CentOS 8+, ArchLinux and Ubuntu 23.04+. * setup: handle getty services also via systemd-preset to avoid potential glitches that happen only for the first boot. For example, Fedora 39 had no console available during the first boot. -- Proxmox Support Team Sun, 19 Nov 2023 19:29:01 +0100 pve-container (5.0.5) bookworm; urgency=medium * fix #4765: pct: do not report cpu usage * config permission check: also check access for currently configured bridge * fix #3460: restore: honor 'ignore-unpack-errors' flag for Proxmox Backup Server backup source * fix #3069: vzdump: add 'pbs-entries-max' parameter -- Proxmox Support Team Mon, 18 Sep 2023 16:51:24 +0200 pve-container (5.0.4) bookworm; urgency=medium * setup: fedora: fix regression with wrong systemd-networkd preset for Fedora 37 and newer -- Proxmox Support Team Sat, 24 Jun 2023 15:08:37 +0200 pve-container (5.0.3) bookworm; urgency=medium * migration: only migrate volumes used by the guest not also those that are owned by them (VMID in name) but not referenced in the config * migration: fail when aliased volume are detected, as referencing the same volume multiple times can lead to unexpected behavior in a migration. -- Proxmox Support Team Wed, 21 Jun 2023 13:05:04 +0200 pve-container (5.0.2) bookworm; urgency=medium * setup: systemd-network: use modern values for dhcp-modes, breaks containers using systemd-network with a container systemd before v219 (released 2015). At that time most distros did not yet used systemd for networking, but rather ifupdown, netplan or NetworkManager; and we require CT distros to use systemd v232 or newer due to default unified cgroupv2 hierarchy anyway. * fix #4515: template setup: remove bogus "LXC_NAME" line from /etc/hosts * config modifications: fix hostname/DNS perm check * do not enable system-networkd on first start for Debian 12 and newer, which uses ifupdown by default, causing systemd-networkd-wait-online to fail * setup: enable systemd-networkd via preset for Arch Linux * setup: enable systemd-networkd via preset for Ubuntu 23.04+ -- Proxmox Support Team Fri, 16 Jun 2023 13:35:14 +0200 pve-container (5.0.1) bookworm; urgency=medium * network permissions: implement checks for using a bridge or vnet on create container, update config, backup restore and clone * fix #4457: actively set bridge MTU, if no MTU is defined in the config * api: resize: fork before locking * setup: fedora: support up to Fedora 40 for future proofing * config: implement method to calculate derived properties from a config -- Proxmox Support Team Fri, 09 Jun 2023 10:18:22 +0200 pve-container (5.0.0) bookworm; urgency=medium * rebuild for Debian 12 bookworm release series -- Proxmox Support Team Thu, 25 May 2023 13:57:41 +0200 pve-container (4.4-4) bullseye; urgency=medium * setup: avoid writing truncated machine-id if it didn't exist * memory: set cgroupv2 memory.high to ~99.6% of memory.max hard-limit * memory: enforce memory.high also on hotplug changes * start: warn in case of conflicting lxc.idmap entries * various code improvements (avoiding declarations in conditional statements) -- Proxmox Support Team Thu, 25 May 2023 09:46:20 +0200 pve-container (4.4-3) bullseye; urgency=medium * fix #4460: setup: centos: create /etc/hostname if it does not exist * fix #4470: pct fstrim: ignore bind and read-only mount points * add a timeout when waiting for shutdown if lxc-stop fails * restore: clean up config and firewall config after trying to restore invalid archive * add 'link_down' option to have container network interfaces "unplugged" * allow riscv32/64 containers * cleanup networking related code -- Proxmox Support Team Thu, 16 Mar 2023 15:56:32 +0100 pve-container (4.4-2) bullseye; urgency=medium * CentOS & derivates: also support all 9.x point releases -- Proxmox Support Team Tue, 22 Nov 2022 10:25:30 +0100 pve-container (4.4-1) bullseye; urgency=medium * config: only save unique tags when updating them via the API -- Proxmox Support Team Mon, 21 Nov 2022 08:37:39 +0100 pve-container (4.3-6) bullseye; urgency=medium * setup: fix using non-plugin methods to avoid breaking unmanaged CTs * network: let the common tap-plug helper add fdb entries, if needed and supported. -- Proxmox Support Team Sun, 20 Nov 2022 16:33:52 +0100 pve-container (4.3-5) bullseye; urgency=medium * enable systemd-networkd per preset in fedora 37+ * fix #4355: d/control: depend on binutils to ensure objdump is available -- Proxmox Support Team Sat, 19 Nov 2022 11:39:49 +0100 pve-container (4.3-4) bullseye; urgency=medium * improve edge-case parsing and limits for CT networking MTU * assert that the user can indeed set/remove any changed tag * migration: add remote migration foundations including new pct 'remote-migrate' CLI command * migrate: print mapped volume in error -- Proxmox Support Team Thu, 17 Nov 2022 15:02:15 +0100 pve-container (4.3-3) bullseye; urgency=medium * setup: relax matching when detecting systemd version -- Proxmox Support Team Wed, 16 Nov 2022 17:50:52 +0100 pve-container (4.3-2) bullseye; urgency=medium * setup: get init path: switch to resolving link recursively to cope with distros that use a relative symlink for /sbin/init -- Proxmox Support Team Wed, 16 Nov 2022 16:53:26 +0100 pve-container (4.3-1) bullseye; urgency=medium * config: cpuunits: drop description for outdated special value * clamp cpu unit value to the value range of the currently booted cgroup controller * fix #4228: add start parameter to rollback endpoint for automatic restarting of CT * fix #4192: revamp check for systemd version, avoiding some false- positives * fix #3606: drop --inplace from suspend backups * net: implement support for bridge disable mac learning by manually registering FDB entries in that case * devuan: add preliminary support for Devuan 12 Daedalus * fedora: support 37 and add pre-liminary support for 38 -- Proxmox Support Team Sun, 13 Nov 2022 15:27:55 +0100 pve-container (4.2-3) bullseye; urgency=medium * fix #4164: use DHCP=yes instead of DHCP=both in systemd-networkd config * apply pending mountpoint: also hotplug non-volume mount points * support Ubuntu 22.10 Kinetic Kudu -- Proxmox Support Team Fri, 21 Oct 2022 14:56:59 +0200 pve-container (4.2-2) bullseye; urgency=medium * fix #4088: ignore systemd minor version * fix an issue with volume deactivation when moving volumes * fix an issue where when failing to clone a container due to it being locked empty left-over configs would remain -- Proxmox Support Team Tue, 05 Jul 2022 09:23:09 +0200 pve-container (4.2-1) bullseye; urgency=medium * prestart & poststop hook: init REST environment, for example to fix volume activation on external Ceph RBD storages -- Proxmox Support Team Wed, 04 May 2022 08:36:45 +0200 pve-container (4.1-5) bullseye; urgency=medium * setup: add basic NixOS support * migrate: set the target storage id also for unreferenced disks * fix #3424: vzdump: cleanup: wait for active replication * fix #3424: api: snapshot delete: wait for active replication * fix #3917: pct: Ignore fstrim failure in CLI fstrim command * fix #3960: properly set owner in CT setup * api: create/modify: add content type checks * api: reassign volume: allow to reassign to own CT * initial support for Fedora 36 * setup: allow hostname configuration on NixOS -- Proxmox Support Team Wed, 27 Apr 2022 19:01:34 +0200 pve-container (4.1-4) bullseye; urgency=medium * snapshot: implement new activate storage helper * fix #1532: add target-storage support to migration * fix #3635: fix overly-strict pool permission check on create -- Proxmox Support Team Fri, 11 Feb 2022 16:18:45 +0100 pve-container (4.1-3) bullseye; urgency=medium * setup: support upcoming Ubuntu 22.04 Jammy Jellyfish * config: allow 'lazytime' mount option for containers -- Proxmox Support Team Tue, 07 Dec 2021 19:10:54 +0100 pve-container (4.1-2) bullseye; urgency=medium * rollback: improve interaction with snapshot replication * cli: pct: rename 'move_volume' command to 'move-volume' with an alias for backward compatibility * api: move-volume: add move to another container * fix #3721: better version check to avoid false-positive on the check if a Alpine Linux in the container is new enough to support the CIDR format. Fixes static addresses on some old, already EOL, Alpine Linux versions -- Proxmox Support Team Fri, 12 Nov 2021 19:21:22 +0100 pve-container (4.1-1) bullseye; urgency=medium * setup: untaint path to host timezone * setup: also set contents of /etc/timezone * fix #3673: setup: add support for upcomming Ubuntu 21.10 Impish Indri containers * add support for upcomming Fedora 35 * api: clone: don't include snapshot related properties in the target config, similar to the VM clone API endpoint. * restore: sanitize config: use task log warn method to record that Proxmox VE could not restore the container 1:1 if the config contained special `lxc.` keys and the user is not root. -- Proxmox Support Team Thu, 14 Oct 2021 13:12:58 +0200 pve-container (4.0-11) bullseye; urgency=medium * fix support for unmanaged containers * pct status: mark suspend as experimental * destroy: remove pending volumes as well * setup: drop copying binfmt qemu-static executable for cross-architecture containers, that should be handled by the kernel opening the binfmt helper immediately on registering. * setup: alpine: also use CIDR format for newer versions (>= 3.13) -- Proxmox Support Team Thu, 07 Oct 2021 08:17:44 +0200 pve-container (4.0-10) bullseye; urgency=medium * centos (and derivatives): set locale.conf to c.UTF-8 if it does not yet exists on template extraction. This avoids systemd-firstboot hanging due to prompting the user on a disconnected console. * opensuse: pre-set locale/timezone to avoid systemd-firstboot hang on prompt in a similar spirit as with centos above * partially fix #3471: setup: centos: net: add missing UUID to ifcfg to improve compatibility with NetworkManager (the default since CentOS 8) * partially fix #3471: setup: centos: net: fix avoid setting the IPV6ADDR config option to the literal "auto" for SLAAC * partially fix #3471: setup: centos: net: set DNS also per iface config -- Proxmox Support Team Wed, 29 Sep 2021 22:14:19 +0200 pve-container (4.0-9) bullseye; urgency=medium * pct cpuset: use limiting cgroup * pct cpuset: show effective values * fix #3478: abort container creation on arch detection timeout * allow nesting to be changed for VM.Allocate on unprivileged containers * skip features when restoring an unprivileged container as privileged * api: limit priv -> unpriv change on container restore to VM.Allocate -- Proxmox Support Team Thu, 5 Aug 2021 16:10:12 +0200 pve-container (4.0-8) bullseye; urgency=medium * config: sync storage ACL checks with qemu-server -- Proxmox Support Team Thu, 8 Jul 2021 12:29:36 +0200 pve-container (4.0-7) bullseye; urgency=medium * fix #3506: config: fix removing the cpulimit of a running CT -- Proxmox Support Team Tue, 06 Jul 2021 15:48:14 +0200 pve-container (4.0-6) bullseye; urgency=medium * ensure container config dir exists before trying to write seccomp config files to it -- Proxmox Support Team Tue, 06 Jul 2021 08:27:12 +0200 pve-container (4.0-5) bullseye; urgency=medium * start: detect and log possible problematic (old) container when running with new default, pure cgroup v2 setup. -- Proxmox Support Team Mon, 05 Jul 2021 18:56:13 +0200 pve-container (4.0-4) bullseye; urgency=medium * cgroupv2: restore usual devices controller behavior via ia userns.conf.d/ file * disable btrfs ioctls for unprivileged containers via seccomp * fix subvolume creation on btrfs where quotas are used * bump minimum required lxc-pve version to 4.0.9-2 -- Proxmox Support Team Mon, 05 Jul 2021 09:57:25 +0200 pve-container (4.0-3) bullseye; urgency=medium * pct CLI: correctly handle 'warnings' task status * fix #3421: only rely on the storage content-type to check if it can host container. This allows custom storage plugins to support 'rootfs' images -- Proxmox Support Team Thu, 24 Jun 2021 08:08:30 +0200 pve-container (4.0-2) bullseye; urgency=medium * api: vmstatus: make template property optional * migrate: remove deprecated force parameter * configure cpu/cpuset/memory cgroupv2 values * pct exec: explicitly check if container is running at the PVE side already * config: limit description/comment length to 8 KiB * clone: clear the cloned containers `/etc/machine-id` when systemd is in use, or that file exists. This ID needs to be unique as else various issues, like MAC address duplications on Linux bridges, can happen * migrate: enforce that rootdir content type is available -- Proxmox Support Team Mon, 21 Jun 2021 10:40:39 +0200 pve-container (4.0-1) bullseye; urgency=medium * re-build for Proxmox VE 7 / Debian Bullseye -- Proxmox Support Team Thu, 13 May 2021 14:02:10 +0200 pve-container (3.3-5) pve; urgency=medium * backup: keep CT template status also for non-root restores * fix #3313: restore: use unprivileged status from backup archive config as default for restored CT * pct push: do not mistakenly recognize the zero root UID/GID value as error * setup: fedora: allow upcoming Fedora 34 -- Proxmox Support Team Tue, 20 Apr 2021 14:13:37 +0200 pve-container (3.3-4) pve; urgency=medium * fix #3176: allow development Devuan versions, improve version detection * fix restore of containers with 'devuan' as ostype -- Proxmox Support Team Wed, 17 Feb 2021 08:59:25 +0100 pve-container (3.3-3) pve; urgency=medium * make formatting image with ext4 less noisy * api: destroy: add 'destroy-unreferenced-disks' parameter * use monitor commands to freeze on pure-v2 setups * restore: add more informational messages * fix #3275: remove old FW config when restoring -- Proxmox Support Team Thu, 28 Jan 2021 17:12:35 +0100 pve-container (3.3-2) pve; urgency=medium * improve restoring PBS archive: avoid missing restore of firewall config -- Proxmox Support Team Wed, 09 Dec 2020 12:49:29 +0100 pve-container (3.3-1) pve; urgency=medium * d/rules: do not try to start or enable system-pve\x2dcontainer.slice on update * CGroups: re-use factored-out PVE::CGroup module as base * deactivate volumes after storage migrate * vzdump: allow relative exclude patterns for snapshot and stop mode, to make the behavior consistent across all backup modes * vzdump: pass along exclude patterns to proxmox-backup-client -- Proxmox Support Team Wed, 25 Nov 2020 13:51:03 +0100 pve-container (3.2-4) pve; urgency=medium * fix #3161: snapshot creation: only check volumes for fsfreeze * setup: Devuan: add support for stable Beowulf and testing Chimaera -- Proxmox Support Team Mon, 23 Nov 2020 19:47:44 +0100 pve-container (3.2-3) pve; urgency=medium * improve numbering scheme detection for CentOS Stream releases * pct fstrim: add 'ignore-mountpoints' parameter * add support for Fedora 33 * add support for Ubuntu 20.10 Groovy Gorilla * fix #2991, #2528: snapshot creation: fsfreeze mountpoints, if underlying FS requires it -- Proxmox Support Team Mon, 16 Nov 2020 16:41:00 +0100 pve-container (3.2-2) pve; urgency=medium * fix #2938: increase limit of max cores from 128 to 8192 * fix #3016: clone: do not copy snapshot config * skip additional virtual filesystems when sycing a containers namespace -- Proxmox Support Team Tue, 22 Sep 2020 10:54:10 +0200 pve-container (3.2-1) pve; urgency=medium * improve feedback for failed Container startup * allow one to enable debug level logging to the start task log * setup: add kali-rolling as supported release -- Proxmox Support Team Wed, 09 Sep 2020 21:21:15 +0200 pve-container (3.1-13) pve; urgency=medium * do the activation of storage volumes outside of the containers mount namespace to avoid issues when it's required to activate the underlying storage * fix passing the offline storage migration bandwidth limit * fix #2790: volume resize: fix API behavior in the case where the disk volume has already the exact size requested * allow one to configure up to 32 network interfaces -- Proxmox Support Team Thu, 27 Aug 2020 12:48:18 +0200 pve-container (3.1-12) pve; urgency=medium * backup: reduce verbosity of logging when syncing filesystems in snapshot mode -- Proxmox Support Team Fri, 24 Jul 2020 11:42:23 +0200 pve-container (3.1-11) pve; urgency=medium * fix #2820: don't hotplug over existing mpX * setup/debian: use CIDR for Debian Buster and newer * vzdump: set heuristic task size information for Proxmox Backup Server target storage * cgroup: get old swap value when hotplugging only memory -- Proxmox Support Team Mon, 13 Jul 2020 13:32:55 +0200 pve-container (3.1-10) pve; urgency=medium * improve snapshot mode backups with a Proxmox Backup Server as target -- Proxmox Support Team Thu, 09 Jul 2020 18:12:11 +0200 pve-container (3.1-9) pve; urgency=medium * fix #2778: use vm_start instead of systemctl to start/restart container * add helper to get reason for mounpoint backup exclusion * fix #1423: add timezone config option -- Proxmox Support Team Thu, 09 Jul 2020 13:55:45 +0200 pve-container (3.1-8) pve; urgency=medium * lxc: fall back to unmanaged when no OS detected and no /etc/os- release file found * adapt network create hook to new pve-network version, if installed -- Proxmox Support Team Mon, 08 Jun 2020 17:39:27 +0200 pve-container (3.1-7) pve; urgency=medium * fix #2655: setup securetty during template fixup also for centos version 7 and newer -- Proxmox Support Team Thu, 28 May 2020 15:29:13 +0200 pve-container (3.1-6) pve; urgency=medium * avoid using LXC CLI tools for CT freeze/unfreeze and improve support for both cgroups v1 and v2 freezer -- Proxmox Support Team Fri, 15 May 2020 16:21:19 +0200 pve-container (3.1-5) pve; urgency=medium * fix: #2124 add zstd * create_vm: avoid premature write_config caused by update_pct_config * api/destroy: repeat early checks after locking * vzdump: use new pbs option -- Proxmox Support Team Tue, 5 May 2020 11:23:42 +0200 pve-container (3.1-3) pve; urgency=medium * add 'force' to destroy-vm to allow destroying running containers * whitelist lxc.cgroup2.* raw keys * consider lxc.cgroup2.cpuset.cpus as an explicit cpuset to not try to override it with a cgroupv1 entry * support cpuset cgroupv2 controller for writing lxc configs * improve cgroup controller version discovery -- Proxmox Support Team Wed, 29 Apr 2020 11:22:13 +0200 pve-container (3.1-2) pve; urgency=medium * Use foreach_volume instead of foreach_mountpoint-variants * Use parse_volume instead of parse_ct-variants * Use new storage_migrate interface -- Proxmox Support Team Thu, 9 Apr 2020 08:50:54 +0200 pve-container (3.1-1) pve; urgency=medium * rework cgroup handling for initial cgroupv2 support * add required configuration changes for lxc-4.0 with now-upstream container cgroup isolation -- Proxmox Support Team Mon, 06 Apr 2020 14:14:50 +0200 pve-container (3.0-24) pve; urgency=medium * For clone+copy features, make sure a valid format for the target is supported * Rely on template_create to check whether creating a template is possible * fix #1904: convert to base image when moving a volume of a template * move_volume: if deleting old volume fails, add it as unused * VZDump: mark template disks as ro * Implement volume-related helpers and use new foreach_volume -- Proxmox Support Team Mon, 30 Mar 2020 09:35:57 +0200 pve-container (3.0-23) pve; urgency=medium * lxc_config: mount /sys as mixed for unprivileged by default to avoid issues with recent systemd versions running inside the container -- Proxmox Support Team Thu, 19 Mar 2020 19:02:48 +0100 pve-container (3.0-22) pve; urgency=medium * Fix mounting ZFS snapshots whose dataset is not mounted below '/' * fix #2580: api/delete: drop CT from HA resources if purge is set * setup: warn on unknown os-release ID * allow restoring non-volume backups again -- Proxmox Support Team Mon, 16 Mar 2020 09:09:45 +0100 pve-container (3.0-21) pve; urgency=medium * fix #2611: use correct operation in get_bandwidth_limit for migration limit * setup/ubuntu: add upcoming 20.04 focal release * vzdump: add support for proxmox backup server -- Proxmox Support Team Tue, 03 Mar 2020 12:00:48 +0100 pve-container (3.0-20) pve; urgency=medium * add mknod feature flag * set lxc.seccomp.notify.cookie to the vmid * llow reading snapshot config for VM.Audit * fix #2598: activate volumes before mounting in stop mode backup * apply pending: do cleanup pending between, not during, change/delete loop -- Proxmox Support Team Thu, 20 Feb 2020 13:59:00 +0100 pve-container (3.0-19) pve; urgency=medium * fix fsck command for ceph RBD backed volumes, map and unmap them * fix #2560: adapt some sysctl values for high CT counts * fix #2568: hotplug: fix typo for 'cpu.shares' * setup: allow all Centos 8.x stable versions -- Proxmox Support Team Mon, 27 Jan 2020 18:53:00 +0100 pve-container (3.0-18) pve; urgency=medium * undo the display change from 3.0-17 for now -- Proxmox Support Team Mon, 20 Jan 2020 09:29:23 +0100 pve-container (3.0-17) pve; urgency=medium * enable centos 8.1 containers * more consistent display of unnamed containers (add a space between 'CT' and the number) -- Proxmox Support Team Mon, 20 Jan 2020 08:44:38 +0100 pve-container (3.0-16) pve; urgency=medium * replace the deprecated DHCP=none with DHCP=no in .network units on systemd based containers * fix an issue where when debugging container startup running them directly via `lxc-start` instead of `pct start`, the prestart hook would mount containers relative to the current working directory instead of where they're supposed to be mounted -- Proxmox Support Team Thu, 02 Jan 2020 09:37:08 +0100 pve-container (3.0-15) pve; urgency=medium * fix #2512: post-stop: unmount stage mps before cleanup * post-stop-hook: unmount before deactivating storages -- Proxmox Support Team Mon, 16 Dec 2019 16:04:39 +0100 pve-container (3.0-14) pve; urgency=medium * fix bindmounting with staged mount points -- Proxmox Support Team Tue, 26 Nov 2019 18:27:41 +0100 pve-container (3.0-13) pve; urgency=medium * move applying pending changes from pre-start to post-stop, as we can regenerate the LXC config safely there. -- Proxmox Support Team Fri, 22 Nov 2019 09:52:53 +0100 pve-container (3.0-12) pve; urgency=medium * implement CT mountpoint hotplugging, for host running 5.3 or newer Linux kernel * implement container reboot over API and CLI * add 'tags' config option for adding meta information to CT -- Proxmox Support Team Wed, 20 Nov 2019 19:27:34 +0100 pve-container (3.0-11) pve; urgency=medium * add PVE::LXC::Tools * change hooks to use new helper * config: whitelist lxc.hook.version * fix #2453: actually reflect random MAC address selection in config * fix #2456 setting bind-mount through API/CLI is broken * improve test reliability in absence of running pmxcfs * follow refactoring in pve-cluster -- Proxmox Support Team Mon, 18 Nov 2019 12:08:15 +0100 pve-container (3.0-10) pve; urgency=medium * support Fedora 31 as Container distribution * minor adaptions of pending changed related code * setup: move host architecture translation from pve-common to container -- Proxmox Support Team Tue, 29 Oct 2019 07:32:43 +0100 pve-container (3.0-8) pve; urgency=medium * fix issue where TTYs aren't correctly set after restore * ensure that lxc.* entries are restored only once * add Ubuntu 19.10 Eoan as supported * fix #2412: ct destroy: only delete config after deleted from pools and Firewall * implement basic pending changes for running containers * fix #1291: add purge option for destroy vm api call, allows one to remove any reference of this CT from backup and replication jobs. * add check to resize disk if current size could not be determined -- Proxmox Support Team Fri, 18 Oct 2019 22:04:12 +0200 pve-container (3.0-7) pve; urgency=medium * mountpoints: create parent dirs with correct owner * setup: allow CentOS 5 and CentOS 8 * do not leave fstrim lock if initial mount-all-volumes procedure fails -- Proxmox Support Team Tue, 03 Sep 2019 07:21:18 +0200 pve-container (3.0-5) pve; urgency=medium * vzdump: always add (empty) firewall config and improve handling of restoring it from archive -- Proxmox Support Team Fri, 26 Jul 2019 12:34:32 +0200 pve-container (3.0-4) pve; urgency=medium * setup CT getty: ensure the getty.target is not masked and improve the logic which ensures that only the correct getty services are enabled * fix #1042: inotify: increase watches, instances & queue default limits * remove obsolete lxc@.service.d * config: whitelist lxc.seccomp.notify.proxy/cookie * add support for debian bullseye/sid -- Proxmox Support Team Fri, 19 Jul 2019 16:03:22 +0200 pve-container (3.0-3) pve; urgency=medium * fix #1451: allow one to add mount options to CT mountpoints * fix #2270: allow custom lxc options to be restored as root -- Proxmox Support Team Thu, 11 Jul 2019 19:25:12 +0200 # Older entries have been removed from this changelog. # To read the complete changelog use `apt changelog pve-container`.